一句话摘要

20 段药物诱导睡眠内镜(DISE)录像由 12 名评估者(7 名初级、5 名资深)独立判读,另有一个未经任务训练的通用人工智能模型参与评估,比较 VOTE 分型的评分者间一致性、治疗决策差异及与专家共识的一致性;治疗建议完全一致率:资深 70%、初级 55%、AI 50%;分型判读比分级更可重复,AI 可作辅助但未达专家水平。

为什么重要

把 DISE 判读的可靠性问题直接量化,并把通用人工智能模型放入同一比较框架,为经验驱动判读的标准化与自动化提供基准数据。

英文摘要原文

Purpose To evaluate the inter-rater reliability of DISE interpretation using the VOTE classification, assess variability in therapeutic decision-making, and explore the potential role of artificial intelligence (AI) in DISE evaluation. Methods Twenty DISE recordings were retrospectively and independently evaluated by 12 raters (7 junior and 5 senior) and by a general-purpose AI model without task-specific training. Inter-rater agreement among human raters for obstruction grading and pattern classification was assessed using percentage agreement, Fleiss' kappa, and weighted kappa. Agreement with a reference standard (unanimous expert consensus) was analyzed. Treatment proposals were evaluated using exact match ratio and Jaccard similarity. Results At baseline, agreement among human raters ranged from 43.6% to 68.0% for obstruction grading (weighted κ, 0.255-0.425) and from 60.8% to 79.3% for collapse pattern (Fleiss' κ, 0.287-0.370). Senior raters showed higher baseline agreement than junior raters across all anatomical levels for collapse pattern and at three of four levels for obstruction grading. Agreement with the expert consensus ranged from 70.0% to 90.0% for senior raters and from 35.0% to 85.0% for AI in baseline grading, and from 75.0% to 95.0% and 50.0% to 80.0%, respectively, in baseline pattern classification. For therapeutic recommendations, exact agreement was 70.0% for senior raters, 55.0% for junior raters, and 50.0% for AI; mean Jaccard similarity was 0.867, 0.833, and 0.742, respectively. Conclusions DISE interpretation remains complex and operator-dependent. Pattern classification appears more reproducible than grading. While a non-task-specific AI model captured clinically relevant patterns, it did not match expert performance in complex decision-making. AI may serve as a supportive tool, particularly for less experienced clinicians.

所属章节

睡眠障碍病理生理

药物诱导睡眠内镜 评分者间信度 VOTE 分型 人工智能

条目编号 P132 · 元数据经 Crossref / Europe PMC 回查